aboutsummaryrefslogtreecommitdiff
path: root/Python/pywarpx/picmi.py
diff options
context:
space:
mode:
authorGravatar MaxThevenet <mthevenet@lbl.gov> 2019-07-12 11:05:28 -0700
committerGravatar MaxThevenet <mthevenet@lbl.gov> 2019-07-12 11:05:28 -0700
commit663ba2f43b1e442737d4d6131b4fc6cc503b7230 (patch)
treeff159d789fc3efbf9899a384045d3170f8987c5b /Python/pywarpx/picmi.py
parent549db2f2f57a1bf5a00ebcc3f9faf7da8908734c (diff)
downloadWarpX-663ba2f43b1e442737d4d6131b4fc6cc503b7230.tar.gz
WarpX-663ba2f43b1e442737d4d6131b4fc6cc503b7230.tar.zst
WarpX-663ba2f43b1e442737d4d6131b4fc6cc503b7230.zip
fix some typos in pywarpx
Diffstat (limited to 'Python/pywarpx/picmi.py')
-rw-r--r--Python/pywarpx/picmi.py13
1 files changed, 4 insertions, 9 deletions
diff --git a/Python/pywarpx/picmi.py b/Python/pywarpx/picmi.py
index 3cbefc920..eb74d854f 100644
--- a/Python/pywarpx/picmi.py
+++ b/Python/pywarpx/picmi.py
@@ -381,16 +381,11 @@ class ElectromagneticSolver(picmistandard.PICMI_ElectromagneticSolver):
pywarpx.warpx.pml_ncell = self.pml_ncell
# --- Same method names are used, though mapped to lower case.
- pywarpx.warpx.maxwell_fdtd_solver = self.method
+ pywarpx.algo.maxwell_fdtd_solver = self.method
if self.cfl is not None:
pywarpx.warpx.cfl = self.cfl
- if self.stencil_order is not None:
- pywarpx.interpolation.nox = self.stencil_order[0]
- pywarpx.interpolation.noy = self.stencil_order[1]
- pywarpx.interpolation.noz = self.stencil_order[2]
-
class ElectrostaticSolver(picmistandard.PICMI_ElectrostaticSolver):
def initialize_inputs(self):
@@ -570,7 +565,7 @@ class FieldDiagnostic(picmistandard.PICMI_FieldDiagnostic):
if self.write_dir is not None:
plot_file = self.write_dir + '/plotfiles/plt'
pywarpx.amr.check_consistency('plot_file', plot_file, 'The plot directory must be the same for all simulation frame diagnostics')
- pywarpx.warpx.plot_file = plot_file
+ pywarpx.amr.plot_file = plot_file
class ElectrostaticFieldDiagnostic(picmistandard.PICMI_ElectrostaticFieldDiagnostic):
def initialize_inputs(self):
@@ -581,7 +576,7 @@ class ElectrostaticFieldDiagnostic(picmistandard.PICMI_ElectrostaticFieldDiagnos
if self.write_dir is not None:
plot_file = self.write_dir + '/plotfiles/plt'
pywarpx.amr.check_consistency('plot_file', plot_file, 'The plot directory must be the same for all simulation frame diagnostics')
- pywarpx.warpx.plot_file = plot_file
+ pywarpx.amr.plot_file = plot_file
class ParticleDiagnostic(picmistandard.PICMI_ParticleDiagnostic):
@@ -600,7 +595,7 @@ class ParticleDiagnostic(picmistandard.PICMI_ParticleDiagnostic):
if self.write_dir is not None:
plot_file = self.write_dir + '/plotfiles/plt'
pywarpx.amr.check_consistency('plot_file', plot_file, 'The plot directory must be the same for all simulation frame diagnostics')
- pywarpx.warpx.plot_file = plot_file
+ pywarpx.amr.plot_file = plot_file
# ----------------------------